XLW (EC) Auto Tensile Tester can be used to measure tensile, peeling, deformation, tearing, heat sealing, adhesive, puncture force, opening force and low speed unwrapping force as well as other performance of plastic films, composite materials, soft package materials, plastic flexible tube, adhesives, adhesive tape, label stickers, medical plasters, release paper, protection films, combined caps, aluminium foil, diaphragm, back sheets, non-woven fabrics, rubber, paper, etc.
Product Features
Professional Technology
- Better than 0.5% of full scale effectively ensures accurate test results
- Support bidirectional testing modes including stretching and compression and test speed could be adjusted freely
- 8 independent test modes are available, including tensile strength, peeling force, tearing force, heat sealing and other performance test.
- Different test range of load cells and 7 distinct test speeds to meet different test requirements
- Pneumatic clamping system provides the even clamping force for specimen to ensure the accuracy of test results
- Intelligent designs of over-travel protection, overload protect, and automatic position reset for safe test operation
- Professional operating software support statistical analysis of group specimens, and export test results in different units
- Support LystemTM Lab Data Sharing System for uniform and systematic management of test results and test reports
High-end
XLW (EC) utilizes Labthink's latest embedded computer system, with better performance than traditional single chip one.
- Embedded computer control system integrates control software with the instruments together
- Professional control system provides safer and more reliable data management as well as test operation
- The instrument can be easily operated by a mouse, a keyboard, and a monitor, without requiring a PC.
- The instrument is equipped with four USB ports and dual internet ports for convenient data transmission.
Standards
This instrument conforms to multiple standards including:
ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T 17590, QB/T 2358, QB/T 1130
Applications
This instrument is equipped with more than 100 grips for tests of more than 1000 materials. And customization is also available for special material tests. Examples of instrument applications:
Basic Applications |
Shearing Test |
Test of Tensile Strength and Elongation Rate |
Test of Tensile Strength at Break |
Tear Resistance Test |
Heatseal Strength Test |
90 Degree Peel Test |
180 Degree Peel Test |
Tensile Strength Test at Defined Elongation |
Extended Applications (Additional Accessories Required) |
Puncture Test of Hypodermic Needles in Artificial Skin | Puncture Test of Films |
Puncture Test of Infusion Bags | Puncture/Pullout Test of Flexible Rubber Closures |
Opening Resistance Test of Combined Covers | Tear Test of ZD - Type Caps |
Opening Force Test of Oral Liquid Caps | Puncture/Pullout Test of Oral Liquid Caps |
90 Degree Pullout Test of Infusion Bag Caps | Pullout Test of Infusion Bag Caps |
23 Degree Pullout Test of Bottle Caps | Puncture/Pullout Test of Bottle Caps or Rubber Closures |
90 Degree Peel Test of Adhesive Tapes | Tear Resistance Test of Adhesive Binding Books |
90 Degree Peel Test of Water-soluble Plasters | Tear Resistance Test of Adhesives |
Adhesive Strength Test (soft) | Adhesive Strength Test (hard) |
Peel Test of Flexible Tube Caps | Removal Force of Pipes and Pipe Joints |
Pullout Test of Cosmetic Brush Hair | Pullout Test of Tooth Brush Hair |
Tensile Strength of Ropes at Break | Opening Force Test of Jelly Cups and Yogurt Cups |
Peel Test of Cup Films | Pullout Test of Rubber Stoppers |
45 Degree Peel Test of Bottle Membranes | Tensile Strength of Sealing Bags |
Peel Test of Magnetic Cores | 90 Degree Peel Test of Magnetic Cards |
Tear Resistance of Heat Sealing Films | Separating Force of Protection Films |
Peel Test of Release Paper | Tear Test Using Trouser Method |
Unwrapping Force of Adhesive Tapes | Compressive Resistance of Plastic Bottles |
20 Degree Peel Test | 135 Degree Peel Test of Plugs |
Peeling Grips of Floating Rollers | Eccentric Grips |
Wide Sample Grips | Japanese Sample Grips |
British Sample Grips | Tensile Strength of Contact Lenses at Break |
Compression Resistance of Jelly Cups | Compression Resistance of Package |
Compression Resistance of Sponge | |
Technical Specifications
Specifications | XLW (EC) Auto Tensile Tester |
Load Cell Capacity | 500 N (standard) 50 N, 100 N, 250 N (optional) |
750 N, 1000N (Customization Available) |
Accuracy | Better than 0.5% FS |
Test Speed | Forward 50, 100, 150, 200, 250, 300, 500 mm/min Backward 50, 100, 150, 200, 250, 300, 500 mm/min |
Number of Specimens | 1 |
Specimen Width | 30 mm (Standard Grip) |
50 mm (Optional Grip) |
Clamping Way | Pneumatic Specimen Clamp |
Gas Supply | Air(outside of supply scope) |
Gas Supply Pressure | 0.5 MPa ~ 0.7 MPa |
Stroke | 950 mm |
Instrument Dimension | 450 mm (L) x 450 mm (W) x 1410 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 70 kg |
Configurations
- Standard Configurations
- Instrument, Professional Software, LCD Monitor, Keyboard, Mouse, Universal Grips and Pneumatic Clamping System
- Optional Parts
- Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips and Printer (compatible with PCL3 language)
- Note
- 1. The gas supply port of this instrument is Φ4mm PU Tubing;
2. Customers will need to prepare for gas supply.
Contact Us! We can help you select or customize the proper unit for your test requirements.